Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 69
Filter
1.
Ultrasonography ; : 323-332, 2023.
Article in English | WPRIM | ID: wpr-969225

ABSTRACT

Purpose@#This study aimed to evaluate the role of Doppler ultrasound (US) and elastography to identify residual breast cancer for patients showing near complete response following chemotherapy on magnetic resonance imaging (MRI). @*Methods@#Between September 2016 and January 2018, 40 breast cancer patients who showed near complete response (either tumor size ≤0.5 cm or lesion-to-background parenchymal signal enhancement ratio ≤1.6) on MRI following neoadjuvant chemotherapy were prospectively enrolled. After excluding seven women who did not undergo Doppler US and elastography, 33 women (median age, 49 years; range, 32 to 67 years) were analyzed. On the day of surgery, women underwent Doppler US and elastography for tumor bed prior to US-guided core needle biopsy. Histopathologic results of biopsy and surgery were evaluated. Negative predictive value (NPV) and false negative rate (FNR) of biopsy and the combined Doppler US and elastography were analyzed, respectively. @*Results@#After surgery, nine women had residual cancers and 24 women had pathologic complete response. The NPV and FNR of biopsy were 92% (24 of 26) and 22% (2 of 9), respectively. The NPV and FNR of combined Doppler US and elastography were 100% (14 of 14) and 0% (0 of 9), respectively. All of nine women with residual cancers had positive vascularity or elasticity. Two women with false-negative biopsy results, having 0.3 cm or 2.5 cm ductal carcinoma in situ at surgery, showed positive vascularity or elasticity. @*Conclusion@#Tumor bed showing positive vascularity or elasticity indicates residual breast cancer for patients showing near complete response on MRI following chemotherapy.

2.
Korean Journal of Radiology ; : 866-877, 2022.
Article in English | WPRIM | ID: wpr-938777

ABSTRACT

Objective@#The optimal imaging approach for evaluating pathological nipple discharge remains unclear. We investigated the value of adding ductography to ultrasound (US) for evaluating pathologic nipple discharge in patients with negative mammography findings. @*Materials and Methods@#From July 2003 to December 2018, 101 women (mean age, 46.3 ± 12.2 years; range, 23–75 years) with pathologic nipple discharge were evaluated using pre-ductography (initial) US, ductography, and post-ductography US. The imaging findings were reviewed retrospectively. The standard reference was surgery (70 patients) or > 2 years of followup with US (31 patients). The diagnostic performances of initial US, ductography, and post-ductography US for detecting malignancy were compared using the McNemar’s test or a generalized estimating equation. @*Results@#In total, 47 papillomas, 30 other benign lesions, seven high-risk lesions, and 17 malignant lesions were identified as underlying causes of pathologic nipple discharge. Only eight of the 17 malignancies were detected on the initial US, while the remaining nine malignancies were detected by ductography. Among the nine malignancies detected by ductography, eight were detected on post-ductography US and could be localized for US-guided intervention. The sensitivities of ductography (94.1% [16/17]) and post-ductography US (94.1% [16/17]) were significantly higher than those of initial US (47.1% [8/17]; p = 0.027 and 0.013, respectively). The negative predictive value of post-ductography US (96.9% [31/32]) was significantly higher than that of the initial US (83.3% [45/54]; p = 0.006). Specificity was significantly higher for initial US than for ductography and post-ductography US (p = 0.001 for all). @*Conclusion@#The combined use of ductography and US has a high sensitivity for detecting malignancy in patients with pathologic nipple discharge and negative mammography. Ductography findings enable lesion localization on second-look post-ductography US, thus facilitating the selection of optimal treatment plans.

3.
Journal of Breast Cancer ; : 131-139, 2022.
Article in English | WPRIM | ID: wpr-925165

ABSTRACT

This study aimed to evaluate the imaging and pathological findings in axillary lymph nodes in patients with breast cancer who received concurrent ipsilateral coronavirus disease 2019 (COVID-19) vaccination. Of the 19 women with breast cancer who received concurrent COVID-19 vaccination shot in the arm ipsilateral to breast cancer, axillary lymphadenopathy was observed in 84.2% (16 of 19) of patients on ultrasound (US) and 71.4% (10 of 14) of patients on magnetic resonance imaging (MRI), and 21.0% (4 of 19) of patients were diagnosed with metastasis. Abnormal US and MRI findings of cortical thickening, effacement of the fatty hilum, round shape, and asymmetry in the number or size relative to the contralateral side were noted in more than half of the non-metastatic and metastatic lymph nodes; however, statistical significance was not noted. Axillary lymphadenopathy is commonly observed in patients with breast cancer who receive concurrent ipsilateral COVID-19 vaccination without specific differential imaging features. Thus, understanding the limitations of axillary imaging and cautious interpretation is necessary to avoid overestimation or underestimation of the axillary disease burden.

4.
Korean Journal of Radiology ; : 867-879, 2021.
Article in English | WPRIM | ID: wpr-902452

ABSTRACT

Objective@#To compare the screening performance of diffusion-weighted (DW) MRI and combined mammography and ultrasound (US) in detecting clinically occult contralateral breast cancer in women with newly diagnosed breast cancer. @*Materials and Methods@#Between January 2017 and July 2018, 1148 women (mean age ± standard deviation, 53.2 ± 10.8 years) with unilateral breast cancer and no clinical abnormalities in the contralateral breast underwent 3T MRI, digital mammography, and radiologist-performed whole-breast US. In this retrospective study, three radiologists independently and blindly reviewed all DW MR images (b = 1000 s/mm2 and apparent diffusion coefficient map) of the contralateral breast and assigned a Breast Imaging Reporting and Data System category. For combined mammography and US evaluation, prospectively assessed results were used. Using histopathology or 1-year follow-up as the reference standard, cancer detection rate and the patient percentage with cancers detected among all women recommended for tissue diagnosis (positive predictive value; PPV2) were compared. @*Results@#Of the 30 cases of clinically occult contralateral cancers (13 invasive and 17 ductal carcinoma in situ [DCIS]), DW MRI detected 23 (76.7%) cases (11 invasive and 12 DCIS), whereas combined mammography and US detected 12 (40.0%, five invasive and seven DCIS) cases. All cancers detected by combined mammography and US, except two DCIS cases, were detected by DW MRI. The cancer detection rate of DW MRI (2.0%; 95% confidence interval [CI]: 1.3%, 3.0%) was higher than that of combined mammography and US (1.0%; 95% CI: 0.5%, 1.8%; p = 0.009). DW MRI showed higher PPV2 (42.1%; 95% CI: 26.3%, 59.2%) than combined mammography and US (18.5%; 95% CI: 9.9%, 30.0%; p = 0.001). @*Conclusion@#In women with newly diagnosed breast cancer, DW MRI detected significantly more contralateral breast cancers with fewer biopsy recommendations than combined mammography and US.

5.
Korean Journal of Radiology ; : 867-879, 2021.
Article in English | WPRIM | ID: wpr-894748

ABSTRACT

Objective@#To compare the screening performance of diffusion-weighted (DW) MRI and combined mammography and ultrasound (US) in detecting clinically occult contralateral breast cancer in women with newly diagnosed breast cancer. @*Materials and Methods@#Between January 2017 and July 2018, 1148 women (mean age ± standard deviation, 53.2 ± 10.8 years) with unilateral breast cancer and no clinical abnormalities in the contralateral breast underwent 3T MRI, digital mammography, and radiologist-performed whole-breast US. In this retrospective study, three radiologists independently and blindly reviewed all DW MR images (b = 1000 s/mm2 and apparent diffusion coefficient map) of the contralateral breast and assigned a Breast Imaging Reporting and Data System category. For combined mammography and US evaluation, prospectively assessed results were used. Using histopathology or 1-year follow-up as the reference standard, cancer detection rate and the patient percentage with cancers detected among all women recommended for tissue diagnosis (positive predictive value; PPV2) were compared. @*Results@#Of the 30 cases of clinically occult contralateral cancers (13 invasive and 17 ductal carcinoma in situ [DCIS]), DW MRI detected 23 (76.7%) cases (11 invasive and 12 DCIS), whereas combined mammography and US detected 12 (40.0%, five invasive and seven DCIS) cases. All cancers detected by combined mammography and US, except two DCIS cases, were detected by DW MRI. The cancer detection rate of DW MRI (2.0%; 95% confidence interval [CI]: 1.3%, 3.0%) was higher than that of combined mammography and US (1.0%; 95% CI: 0.5%, 1.8%; p = 0.009). DW MRI showed higher PPV2 (42.1%; 95% CI: 26.3%, 59.2%) than combined mammography and US (18.5%; 95% CI: 9.9%, 30.0%; p = 0.001). @*Conclusion@#In women with newly diagnosed breast cancer, DW MRI detected significantly more contralateral breast cancers with fewer biopsy recommendations than combined mammography and US.

6.
Korean Journal of Radiology ; : 297-307, 2021.
Article in English | WPRIM | ID: wpr-875283

ABSTRACT

Objective@#To compare the performance of simulated abbreviated breast MRI (AB-MRI) and full diagnostic (FD)-MRI in distinguishing between benign and malignant lesions detected by MRI and investigate the features of discrepant lesions of the two protocols. @*Materials and Methods@#An AB-MRI set with single first postcontrast images was retrospectively obtained from an FD-MRI cohort of 111 lesions (34 malignant, 77 benign) detected by contralateral breast MRI in 111 women (mean age, 49.8. ± 9.8;range, 28–75 years) with recently diagnosed breast cancer. Five blinded readers independently classified the likelihood of malignancy using Breast Imaging Reporting and Data System assessments. McNemar tests and area under the receiver operating characteristic curve (AUC) analyses were performed. The imaging and pathologic features of the discrepant lesions of the two protocols were analyzed. @*Results@#The sensitivity of AB-MRI for lesion characterization tended to be lower than that of FD-MRI for all readers (58.8– 82.4% vs. 79.4–100%), although the findings of only two readers were significantly different (p 0.05). Fifteen percent (5/34) of the cancers were false-negatives on AB-MRI. More suspicious margins or internal enhancement on the delayed phase images were related to the discrepancies. @*Conclusion@#The overall performance of AB-MRI was similar to that of FD-MRI in distinguishing between benign and malignant lesions. AB-MRI showed lower sensitivity and higher specificity than FD-MRI, as 15% of the cancers were misclassified compared to FD-MRI.

7.
Journal of Pathology and Translational Medicine ; : 16-25, 2021.
Article in English | WPRIM | ID: wpr-874894

ABSTRACT

Characterization of breast cancer molecular subtypes has been the standard of care for breast cancer management. We aimed to provide a review of imaging features of breast cancer molecular subtypes for the field of precision medicine. We also provide an update on the recent progress in precision medicine for breast cancer, implications for imaging, and recent observations in longitudinal functional imaging with radiomics.

8.
Korean Journal of Radiology ; : 1210-1219, 2020.
Article | WPRIM | ID: wpr-833572

ABSTRACT

Objective@#To compare the utility and diagnostic performance of automated breast ultrasound system (ABUS) with that of handheld ultrasound (HHUS) in evaluating pure non-mass enhancement (NME) lesions on breast magnetic resonance imaging (MRI). @*Materials and Methods@#One hundred twenty-six consecutive MRI-visible pure NME lesions of 122 patients with breast cancer were assessed from April 2016 to March 2017. Two radiologists reviewed the preoperative breast MRI, ABUS, and HHUS images along with mammography (MG) findings. The NME correlation rate and diagnostic performance of ABUS were compared with that of HHUS, and the imaging features associated with ABUS visibility were analyzed. @*Results@#Among 126 pure NME lesions, 100 (79.4%) were malignant and 26 (20.6%) were benign. The overall correlation rate was 87.3% (110/126) in ABUS and 92.9% (117/126) in HHUS. The sensitivity and specificity were 87% and 50% for ABUS and 92% and 42.3% for HHUS, respectively, with no significant differences (p = 0.180 and 0.727, respectively). Malignant NME was more frequently visualized than benign NME lesions on ABUS (93% vs. 65.4%, p = 0.001). Significant factors associated with the visibility of ABUS were the size of NME lesions on MRI (p < 0.001), their distribution pattern (p < 0.001), and microcalcifications on MG (p = 0.027). @*Conclusion@#ABUS evaluation of pure NME lesions on MRI in patients with breast cancer is a useful technique with high visibility, especially in malignant lesions. The diagnostic performance of ABUS was comparable with that of conventional HHUS in evaluating NME lesions.

9.
Korean Journal of Radiology ; : 561-571, 2020.
Article | WPRIM | ID: wpr-833516

ABSTRACT

Objective@#To evaluate the clinical utility of ultrafast dynamic contrast-enhanced (DCE)-MRI compared to conventional DCEMRIby studying lesion conspicuity and size according to the level of background parenchymal enhancement (BPE). @*Materials and Methods@#This study included 360 women (median age, 54 years; range, 26–82 years) with 361 who had undergonebreast MRI, including both ultrafast and conventional DCE-MRI before surgery, between January and December 2017. Conspicuitywas evaluated using a five-point score. Size was measured as the single maximal diameter. The Wilcoxon signed-rank test wasused to compare median conspicuity score. To identify factors associated with conspicuity, multivariable logistic regressionwas performed. Absolute agreement between size at MRI and histopathologic examination was assessed using the intraclasscorrelation coefficient (ICC). @*Results@#The median conspicuity scores were 5 at both scans, but the interquartile ranges were significantly different (5-5 atultrafast vs. 4-5 at conventional, p < 0.001). Premenopausal status (odds ratio [OR] = 2.2, p = 0.048), non-mass enhancement(OR = 4.1, p = 0.001), moderate to marked BPE (OR = 7.5, p < 0.001), and shorter time to enhancement (OR = 0.9, p =0.043) were independently associated with better conspicuity at ultrafast scans. Tumor size agreement between MRI andhistopathologic examination was similar for both scans (ICC = 0.66 for ultrafast vs. 0.63 for conventional). @*Conclusion@#Ultrafast DCE-MRI could improve lesion conspicuity compared to conventional DCE-MRI, especially in womenwith premenopausal status, non-mass enhancement, moderate to marked BPE or short time to enhancement.

10.
Korean Journal of Radiology ; : 25-32, 2020.
Article in English | WPRIM | ID: wpr-782172

ABSTRACT

0.05).CONCLUSION: 2-VST of ABUS achieved comparable scan coverage and diagnostic performance to that of conventional 3-VST in women with small breasts.


Subject(s)
Female , Humans , Breast Neoplasms , Breast , Sensitivity and Specificity , Ultrasonography
11.
Journal of the Korean Radiological Society ; : 919-929, 2019.
Article in English | WPRIM | ID: wpr-916839

ABSTRACT

PURPOSE@#This study aimed to analyze the current practices of breast imaging among Korean radiologists.@*MATERIALS AND METHODS@#We invited members of the Korean Society of Breast Imaging (KSBI) working as breast radiologists to participate in a survey on the current practices in breast imaging, and investigated how quality assurance (QA), medical audits, and imaging-histologic discordance were conducted.@*RESULTS@#The survey involved 312 members of the KSBI, and 116 (37%) responded to the 21 questions in the questionnaire. Most of the respondents were women (87%), aged below 50 years (82.7%), and working at university or tertiary hospitals (68.1%), who had varying levels of experience in breast imaging. Of the 116 respondents, 114 (96.6%) followed the Breast Imaging Reporting and Data System (BI-RADS) to interpret breast imaging. Out of 116, 72 (62.1%) interpreted 20 or more mammograms per day, 84 (72.4%) performed 10–30 breast ultrasound scans per day, and 65 (56%) interpreted fewer than 5 breast MRI scans per day. Among the respondents, 82% performed mammography QA, 76.9% evaluated imaging-histologic correlations, and only 38.9% performed medical audits.@*CONCLUSION@#The institutions and working patterns of breast radiologists were diverse. Although many respondents did not conduct medical audits, most of them followed BI-RADS when interpreting breast imaging, performing QA, and evaluating imaging-histologic correlations.

12.
Journal of Breast Disease ; (2): 59-64, 2019.
Article in English | WPRIM | ID: wpr-937771

ABSTRACT

PURPOSE@#This study was designed to verify the effectiveness of Mastocheck, a new diagnostic tool developed with proteomics techniques using plasma proteins. In addition, checked the current state of mammography used for breast cancer screening.@*METHODS@#A total of 305 cases were analyzed (normal 122, breast cancer 183) and used for validation after Mastocheck development. First, screening mammograms of normal patients and pre-diagnosis mammography of cancer patients were reviewed retrospectively. The results were compared with Mastocheck, a newly developed blood test. Imaging tests were blinded and analyzed by dividing the readings of breast specialists and non-breast specialists among radiologists. We confirmed how much better the results would be if only the mammography was used and if both tests were used together.@*RESULTS@#The sensitivity, specificity, and accuracy of mammography alone, reviewed by non-breast specialists among radiologists, were 63.0%, 85.7%, and 71.3%, respectively. In dense breasts, the values were 59.2%, 84.8% and 69.0%, which were too low to be considered interpretable. The sensitivity, specificity and accuracy of the test was 93.9%, 83.8%, and 90.2% when using mammography and Mastocheck together. From these results, an improvement in sensitivity of about 30% and an improvement in accuracy of about 15% or more in concomitant use than mammography alone can be seen.@*CONCLUSION@#Mastocheck can be widely used for screening breast cancer, especially in dense breasts, patients with low accuracy in mammography, and patients with mammography side effects. In addition, it has the advantage of increasing the diagnosis rate when used with mammography, the current screening method of choice.

13.
Ultrasonography ; : 277-287, 2018.
Article in English | WPRIM | ID: wpr-731137

ABSTRACT

This work reviews the evidence on breast imaging for screening (surveillance) in women with a history of breast cancer (BC). Early detection of second BCs in these women improves their prognosis based on studies using mammography (usually with clinical examinations) for surveillance. Cohort studies have estimated that mammography surveillance has moderate sensitivity (65.4%) and good specificity (98.3%), and have shown that these women are at a higher risk of interval BC than age- and breast density-matched women without a history of BC. Studies of adjunct imaging (ultrasound, magnetic resonance imaging) for surveillance that have reported detection and accuracy measures have generally shown that adjunct imaging detected more second BCs than mammography and added substantially to the amount of false-positive results; however, little evidence exists regarding screening efficacy of adjunct imaging as part of routine surveillance.


Subject(s)
Female , Humans , Breast Neoplasms , Breast , Cohort Studies , Mammography , Mass Screening , Prognosis , Sensitivity and Specificity
14.
Journal of Breast Cancer ; : 192-197, 2017.
Article in English | WPRIM | ID: wpr-207529

ABSTRACT

PURPOSE: The aim of our study was to investigate the characteristics of primary and recurrent breast cancers and the correlation between cancer subtypes and detection modes. METHODS: Between 2003 and 2013, 147 cases of recurrent breast cancer in 137 women (mean age, 45.30±10.78 years) were identified via an annual clinical examination using radiological studies among 6,169 patients with a breast cancer history (mean follow-up period, 13.26±1.78 years). Clinical, radiological, and pathological findings including immunohistochemistry findings of primary and recurrent cancers were reviewed. The size of the tumor in primary and recurrent cancers, disease-free survival, methods of surgery, and the recurrence detection modalities were analyzed with respect to the breast cancer subtype. RESULTS: Ipsilateral and contralateral in-breast recurrence occurred in 105, 21 had axillary lymph node recurrence, and 21 had chest wall recurrences. The subtypes of the primary cancers were hormone receptor (HR) positive and human epidermal growth factor receptor 2 (HER2) negative (HR+HER2−) in 57, HER2 positive (HER2+) in 39, and triple-negative type in 51, and the recurrent cancers in each subtype showed the same type as the primary cancer in 84.3% of cases. In the in-breast recurrent cancers, the HR+HER2− cancers were most frequently detected using ultrasonography (15/43) followed by mammography (MG) (11/43). The HER2+ recurrent cancers were most commonly detected using MG (14/31, 45.2%), whereas triple-negative type recurrent cancers most commonly presented as symptomatic masses (15/31) (p=0.028). CONCLUSION: Most recurrent breast cancers showed the same cancer subtype as the primary tumor, and recurrent breast cancer subtypes correlated with the detection modality. Imaging surveillance of survivors of breast cancer might be more beneficial in cases of HR+HER2− type breast cancer or HER2+ type breast cancer than in cases of triple-negative type breast cancer.


Subject(s)
Female , Humans , Breast Neoplasms , Breast , Disease-Free Survival , Follow-Up Studies , Immunohistochemistry , Lymph Nodes , Mammography , Methods , ErbB Receptors , Recurrence , Survivors , Thoracic Wall , Ultrasonography
15.
Journal of Breast Cancer ; : 319-319, 2017.
Article in English | WPRIM | ID: wpr-83447

ABSTRACT

This article was initially published on the Journal of Breast Cancer with a misspelled the grant number.

16.
Cancer Research and Treatment ; : 1088-1096, 2017.
Article in English | WPRIM | ID: wpr-160265

ABSTRACT

PURPOSE: The American College of Surgeons Oncology Group Z0011 trial reported that complete dissection of axillary lymph nodes (ALNs) may not be warranted in women with clinical T1-T2 tumors and one or two involved ALNs who were undergoing lumpectomy plus radiation followed by systemic therapy. The present study was conducted to identify preoperative imaging predictors of ≥ 3 ALNs. MATERIALS AND METHODS: The training set consisted of 1,917 patients with clinical T1-T2 and node negative invasive breast cancer. Factors associated with ≥ 3 involved ALNs were evaluated by logistic regression analysis. The validation set consisted of 378 independent patients. The nomogram was applied prospectively to 512 patients who met the Z0011 criteria. RESULTS: Of the 1,917 patients, 204 (10.6%) had ≥ 3 positive nodes. Multivariate analysis showed that involvement of ≥ 3 nodes was significantly associated with ultrasonographic and chest computed tomography findings of suspicious ALNs (p < 0.001 each). These two imaging criteria, plus patient age, were used to develop a nomogram calculating the probability of involvement of ≥ 3 ALNs. The areas under the receiver operating characteristic curve of the nomogram were 0.852 (95% confidence interval [CI], 0.820 to 0.883) for the training set and 0.896 (95% CI, 0.836 to 0.957) for the validation set. Prospective application of the nomogram showed that 60 of 512 patients (11.7%) had scores above the cut-off. Application of the nomogram reduced operation time and cost, with a very low re-operation rate (1.6%). CONCLUSION: Patients likely to have ≥ 3 positive ALNs could be identified by preoperative imaging. The nomogram was helpful in selective intraoperative examination of sentinel lymph nodes.


Subject(s)
Female , Humans , Breast Neoplasms , Breast , Logistic Models , Lymph Nodes , Mastectomy, Segmental , Multivariate Analysis , Nomograms , Prospective Studies , ROC Curve , Surgeons , Thorax
17.
Investigative Magnetic Resonance Imaging ; : 233-241, 2017.
Article in English | WPRIM | ID: wpr-119937

ABSTRACT

PURPOSE: To report on the current practices in breast magnetic resonance imaging (MRI) in Korea. MATERIALS AND METHODS: We invited the 68 members of the Korean Society of Breast Imaging who were working in hospitals with available breast MRI to participate in a survey on how they performed and interpreted breast MRI. We asked one member from each hospital to respond to the survey. A total of 22 surveys from 22 hospitals were analyzed. RESULTS: Out of 22 hospitals, 13 (59.1%) performed at least 300 breast MRI examinations per year, and 5 out of 22 (22.7%) performed > 1200 per year. Out of 31 machines, 14 (45.2%) machines were 1.5-T scanners and 17 (54.8%) were 3.0-T scanners. All hospitals did contrast-enhanced breast MRI. Full-time breast radiologists supervised the performance and interpreted breast MRI in 19 of 22 (86.4%) of hospitals. All hospitals used BI-RADS for MRI interpretation. For computer-aided detection (CAD), 13 (59.1%) hospitals sometimes or always use it and 9 (40.9%) hospitals did not use CAD. Two (9.1%) and twelve (54.5%) hospitals never and rarely interpreted breast MRI without correlating the mammography or ultrasound, respectively. The majority of respondents rarely (13/21, 61.9%) or never (5/21, 23.8%) interpreted breast MRI performed at an outside facility. Of the hospitals performing contrast-enhanced examinations, 15 of 22 (68.2%) did not perform MRI-guided interventional procedures. CONCLUSION: Breast MRI is extensively performed in Korea. The indication and practical patterns are diverse. The information from this survey would provide the basis for the development of Korean breast MRI practice guidelines.


Subject(s)
Breast Neoplasms , Breast , Diagnosis , Korea , Magnetic Resonance Imaging , Mammography , Surveys and Questionnaires , Ultrasonography
18.
Ultrasonography ; : 281-288, 2016.
Article in English | WPRIM | ID: wpr-731063

ABSTRACT

During the last 15 years, traditional breast cancer classifications based on histopathology have been reorganized into the luminal A, luminal B, human epidermal growth factor receptor 2 (HER2), and basal-like subtypes based on gene expression profiling. Each molecular subtype has shown varying risk for progression, response to treatment, and survival outcomes. Research linking the imaging phenotype with the molecular subtype has revealed that non-calcified, relatively circumscribed masses with posterior acoustic enhancement are common in the basal-like subtype, spiculated masses with a poorly circumscribed margin and posterior acoustic shadowing in the luminal subtype, and pleomorphic calcifications in the HER2-enriched subtype. Understanding the clinical implications of the molecular subtypes and imaging phenotypes could help radiologists guide precision medicine, tailoring medical treatment to patients and their tumor characteristics.


Subject(s)
Humans , Acoustics , Breast Neoplasms , Breast , Classification , Diagnosis , Gene Expression Profiling , Phenobarbital , Phenotype , Precision Medicine , ErbB Receptors , Shadowing Technique, Histology , Ultrasonography
19.
Korean Journal of Radiology ; : 59-68, 2016.
Article in English | WPRIM | ID: wpr-222272

ABSTRACT

OBJECTIVE: To retrospectively evaluate the features of undiagnosed breast cancers on prior screening breast magnetic resonance (MR) images in patients who were subsequently diagnosed with breast cancer, as well as the potential utility of MR-computer-aided evaluation (CAE). MATERIALS AND METHODS: Between March 2004 and May 2013, of the 72 consecutive pairs of prior negative MR images and subsequent MR images with diagnosed cancers (median interval, 32.8 months; range, 5.4-104.6 months), 36 (50%) had visible findings (mean size, 1.0 cm; range, 0.3-5.2 cm). The visible findings were divided into either actionable or underthreshold groups by the blinded review by 5 radiologists. MR imaging features, reasons for missed cancer, and MR-CAE features according to actionability were evaluated. RESULTS: Of the 36 visible findings on prior MR images, 33.3% (12 of 36) of the lesions were determined to be actionable and 66.7% (24 of 36) were underthreshold; 85.7% (6 of 7) of masses and 31.6% (6 of 19) of non-mass enhancements were classified as actionable lesions. Mimicking physiologic enhancements (27.8%, 10 of 36) and small lesion size (27.8%, 10 of 36) were the most common reasons for missed cancer. Actionable findings tended to show more washout or plateau kinetic patterns on MR-CAE than underthreshold findings, as the 100% of actionable findings and 46.7% of underthreshold findings showed washout or plateau (p = 0.008). CONCLUSION: MR-CAE has the potential for reducing the number of undiagnosed breast cancers on screening breast MR images, the majority of which are caused by mimicking physiologic enhancements or small lesion size.


Subject(s)
Adult , Aged , Female , Humans , Middle Aged , Breast/pathology , Breast Neoplasms/diagnosis , Diagnosis, Computer-Assisted/methods , False Negative Reactions , Magnetic Resonance Imaging/methods , Mammography/methods , Retrospective Studies
20.
Journal of Breast Cancer ; : 199-205, 2016.
Article in English | WPRIM | ID: wpr-166632

ABSTRACT

PURPOSE: To evaluate imaging features of pure lobular carcinoma in situ (LCIS) on magnetic resonance imaging (MRI) in patients who underwent immediate re-excision after lumpectomy. METHODS: Twenty-six patients (46.1±6.7 years) with 28 pure LCIS lesions, who underwent preoperative MRI and received curative surgery at our institution between 2005 and 2013, were included in this study. Clinicopathologic features associated with immediate re-excision were reviewed and analyzed using Fisher exact test or the Wilcoxon signed rank test. RESULTS: Of the 28 lesions, 21.4% (6/28, six patients) were subjected to immediate re-excision due to resection margin involvement by LCIS. Nonmass lesions and moderate-to-marked background parenchymal enhancement on MRI were more frequently found in the re-excision group than in the single operation group (100% [6/6] vs. 40.9% [9/22], p=0.018; 83.3% [5/6] vs. 31.8% [7/22], p=0.057, respectively). The median lesion size discrepancy observed between magnetic resonance images and histopathology was greater in the re-excision group than in the single operation group (-0.82 vs. 0.13, p=0.018). There were no differences in the mammographic or histopathologic findings between the two groups. CONCLUSION: Nonmass LCIS lesions or moderate-to-marked background parenchymal enhancements on MRI can result in an underestimation of the extent of the lesions and are associated with subsequent re-excision due to resection margin involvement.


Subject(s)
Humans , Breast Neoplasms , Carcinoma in Situ , Carcinoma, Lobular , Magnetic Resonance Imaging , Mastectomy, Segmental
SELECTION OF CITATIONS
SEARCH DETAIL